Table 11-5. Total Alert Traps - ADTRAN ATLAS 810 Plus User Manual

Adtran network device user manual
Hide thumbs Also See for ATLAS 810 Plus:
  • Q&a (22 pages)
Table of Contents

Advertisement

Chapter 11. SNMP Management
Total Alert
adATLAS800TotalES
adATLAS800TotalSES
adATLAS800TotalSEFS
adATLAS800TotalUAS
adATLAS800TotalCSS
adATLAS800TotalPCV
adATLAS800TotalLES
adATLAS800TotalLCV
11-6
Severity
Warning The total interval errored second threshold has been
exceeded.
Warning The total interval severely errored second threshold has
been exceeded.
Warning The total interval severely errored framing second threshold
has been exceeded.
Major
The total interval unavailable second threshold has been
exceeded.
Warning The total interval controlled slip second threshold has been
exceeded.
Warning The total interval path code violations has been exceeded.
Warning The total interval line errored second threshold has been
exceeded.
Warning The total interval line code violation threshold has been
exceeded.
When one of the Total Alert thresholds is exceeded, the corresponding event
bit is set to 1 in the adDS1TotalAlert variable in the DS1 alert table. When en-
PLUS
abled, ATLAS 810
sends alert traps to each member of the trap destina-
tion list upon detecting status bit changes in adDS1TotalAlert. If you have
previously set the corresponding enable bit = 1 in the adDS1TotalArm vari-
able and adDS1AlertEnable = On, then ATLAS 810
message. A single alert trap message may report multiple event changes.
PLUS
ATLAS 810
clears the event bits after sending the trap message or send-
ing the response to a Get request for the adDS1TotalAlert variable.
Current Alert and Total Alert described above are Near End events.
PLUS
ATLAS 810
also supports Current Alert and Total Alert for the Far End.
Far End alert traps are generated upon status bit changes in
adDS1FarCurrentAlert for Current Alerts and adDS1FarTotalAlert for Total
Alerts. Current and Total Far End Alerts can be disabled by setting the cor-
responding enable bit = 0 in the adDS1FarCurrentArm and
adDS1FarTotalArm variables, respectively. Far End alert traps can also be
disabled by setting adDS1AlertEnable = Off.
PLUS
ATLAS 810

Table 11-5. Total Alert Traps

Description
PLUS
User Manual
sends an alarm trap
61200266L1-1