Chapter 10. Updating Firmware
Updating Firmware using XMODEM
10-2
Before beginning this procedure,
•
you must have a level 2 password for updating any module within
PLUS
ATLAS 810
. Please consult the ATLAS 810
do not know the password.
•
you must obtain the appropriate update file for the particular module
from ADTRAN Technical Support at (888) 4ADTRAN (423-8726).
•
you may want to review Update Firmware on page 6-16.
Instructions for Updating Firmware Using XMODEM
Step
Using a VT-100 terminal emulation communication software
package which contains XMODEM protocol support, log in to
1
PLUS
ATLAS 810
2
Select System Utility / Update Firmware (see Figure 10-1).
Move the cursor to Module Slot, and press
appropriate module slot to update. To update multiple modules of
the same type, select All Modules of a Type from Module Slot.
3
(Only upgradable modules are displayed as choices for Module
Type when updating All Modules of a Type in the ATLAS.)
4
Select XMODEM for Transfer Method.
From Restart Schedule, select the time for the module to perform
5
a restart after completing the update process (see Restart
Schedule on page 6-17).
View Current Update Status to verify the progress of the current
6
firmware update or any errors encountered during the download
process (see Current Update Status on page 6-18).
Select Begin Firmware Update to start the update process. Enter
to confirm the transfer and to set up the module to receive the
Y
XMODEM upload.
7
When ATLAS is ready to receive the XMODEM upload, the menu
screen will clear and display
. If this does not appear, please review the steps
X> to Cancel
above for possible configuration errors.
PLUS
ATLAS 810
Action
.
Awaiting XMODEM Upload...... <CTRL-
User Manual
PLUS
administrator if you
. Select the
Enter
61200266L1-1