State; Status; Rev - ADTRAN ATLAS 810 Plus User Manual

Adtran network device user manual
Hide thumbs Also See for ATLAS 810 Plus:
  • Q&a (22 pages)
Table of Contents

Advertisement

» State
» Status
» Rev
61200266L1-1
Read security:5
Displays whether the module is online of offline. Even though a module is
physically installed, it must be marked
available resource. This parameter allows an installed module to be marked
, which may be useful in system troubleshooting. If you choose
Offline
, the module will not be in alarm condition, but will display
Offline
Once a module is installed, the state must be set to Online in
order for the ATLAS to utilize the module for any data bandwidth.
Read security:5
Displays status information on the ATLAS 810
installed modules as follows:
Online
The module is enabled and is responding to the system
controller's status polls. This is the normal response of the
system.
No Response
The module is enabled but is not responding to the sys-
tem controller's status polls. This response indicates a
problem in the system or that the module is not installed.
Empty
The system controller has not detected the presence of a
module in the system, nor has a module been manually
enabled for this option slot.
The module is installed but has been taken Offline by a
Offline
user. The module is still responding to controller polls.
Offline/No
The module is installed but has been taken Offline by a
user. The module is not responding to polls.
Response:
Not Supported
The module is not supported by the current system con-
figuration.