Appendix A. System Event Logging
Event
ATLAS configuration file loaded into the
system and activated
a
Console login failure
Internal system temperature has returned to
normal
Internal system temperature is too high
Module found
Module removed or not responding
Primary power supply is present but is not
operating properly
SNMP authentication failure
c
System cold start
The backup power supply is operating
properly or has been removed
The backup power supply is present but is
not operating properly
The primary power supply is operating
properly or has been removed
a. Three consecutive login attempts were attempted and failed.
b. Generated if the ATLAS receives an SNMP request from an SNMP manager defined in the ATLAS SNMP commu-
nities list but with a community name that does not match the community name defined in the SNMP communities
list.
c. Generated five seconds after the completion of system initialization.
A-2
Critical
Minor
Critical
Critical
Info
Warning
Critical
b
Info
Normal
Critical
Critical
Critical
Event
a
Call rejected
b
Call rejected
c
Call rejected
Call successfully routed Normal
a. No such number in dial plan.
b. Number is on outgoing reject list.
c. All endpoints busy.
ATLAS 810
Category
Console Log String
System Configuration Uploaded
Login Failure
Internal Temperature Warning Cleared
Internal Temperature Warning
Module Found
Module Not Responding
Main Power Supply Failure
SNMP Authentication Failure
Cold
Backup Power Supply Failure Cleared
Backup Power Supply Failure
Main Power Supply Failure Cleared
Table A-2. Switchboard Events
Category
Console Log String
Warning
<number> rejected: No such number
Normal
<number> rejected: Outgoing reject list
Normal
<number> rejected: Busy
<number> accepted: <slot> <port>
PLUS
User Manual
Table A-1. System Event
61200266L1-1
Need help?
Do you have a question about the ATLAS 810 Plus and is the answer not in the manual?