Table 11-4. Ds1 Current Alert Snmp Traps - ADTRAN ATLAS 810 Plus User Manual

Adtran network device user manual
Hide thumbs Also See for ATLAS 810 Plus:
  • Q&a (22 pages)
Table of Contents

Advertisement

Current Alert
adATLAS800CurrentES
adATLAS800CurrentSES
adATLAS800CurrentSEFS
adATLAS800CurrentUAS
adATLAS800CurrentCSS
adATLAS800CurrentLES
adATLAS800CurrentCV
61200266L1-1
ber of the trap destination list when accumulated error statistics exceed
these threshold values. Table 11-4 describes the alert traps supported by
PLUS
ATLAS 810
for events that have occurred in the last 15-minute interval.
Severity
Warning
The current interval errored second threshold has
been exceeded.
Warning
The current interval severely errored second
threshold has been exceeded.
Warning
The current interval severely errored framing second
threshold has been exceeded.
Major
The current interval is unavailable.
Warning
The current interval path code violations have been
exceeded.
Warning
The current interval line errored second threshold has
been exceeded.
Warning
The current interval line code violation threshold has
been exceeded.
When one of the Current Alert thresholds is exceeded, the corresponding
event bit is set to 1 in the adDS1CurrentAlert variable in the DS1 alert table.
When enabled, ATLAS 810
destination list upon detecting status bit changes in adDS1CurrentAlert. If
you have previously set the corresponding enable bit = 1 in the
adDS1CurrentArm variable and adDS1AlertEnable = On, then
PLUS
ATLAS 810
sends an alert trap message. A single alert trap message
may report multiple event changes. ATLAS 810
ter sending the trap message or sending the response to a Get request for the
adDS1CurrentAlert variable. ATLAS 810
at the beginning of a new 15-minute interval. Total Alert values are cleared
at the beginning of a new 24-hour interval.
Table 11-5 shows the Total Alert Traps, which describe events that have oc-
curred in the last 24-hour interval.
ATLAS 810
Chapter 11. SNMP Management

Table 11-4. DS1 Current Alert SNMP Traps

Description
PLUS
sends alert traps to each member of the trap
PLUS
clears the Current Alert values
PLUS
User Manual
PLUS
clears the event bits af-