2.6.2.5 Wire Power for Optional Auxiliary Devices to Power Relay Board

If an auxiliary device is installed on the system, customer fused or breaker protected power will
need to be provided to the device. The Power Relay Board allows for up to two auxiliary devices
to be installed with a maximum amp draw of 10 amps per device.
Wire customer power for the auxiliary device as follows:
1. Run a 14 AWG (2.5 mm
meters (50 ft.) is the maximum permitted cable length.
2. Locate terminal block TB5 on the Power Relay Board (P/N: 5553301).
3. Secure the wire to TB5 as shown in Figure 2-18. If the auxiliary device is installed at
AUX 1 on TB6, the power should be provided at AUX 2 on TB5. If the auxiliary device is
installed at AUX 2 on TB6, the power should be provided at AUX 2 on TB5.
TP-5554501-B
May 2019
I
NSTRUCTIONS FOR
2
) wire from the auxiliary device to the Control Box Assembly.

Figure 2-17 Power Relay Board Terminal Block TB6

2
) wire from customer power to the Control Box Assembly. 15

Figure 2-18 Power Relay Board Terminal Block TB5