I
N
NSTRUCTIONS FOR
IGHT
2.6.2.7 Wire Power for Mast and Control to Power Relay Board
The mast and control require a 20-30 VDC power supply with a nominal power of 24 VDC. The
system may have an amp draw of up to 20 amps. To wire customer power for the mast and
control:
1. Run a 10 AWG cable (6 mm
Control Box Assembly through one of the cable grips on the side of the control box. Use
10/2 SJOW or equivalent wire. This cable is typically customer supplied, but available as
P/N: 218073 specified by length or P/N: 5594101 for a 15 meter (50 ft.) length cable.
2. Locate terminal block TB1 on the Power Relay Board (P/N: 5553301).
3. Secure the wire to TB1 as shown in Figure 2-22.
2-26
S
L
& I
CAN
ITE
NFLEXION
Figure 2-21 12VDC Input Power Wiring
2
) (maximum length 15 meters) from customer power to the
Figure 2-22 Power Relay Board Terminal Block TB1
Original Instructions
HD
TP-5554501-B
May
2019