Table 1-4 Inflexion Hd (No Rcp/No Lights) - Will Burt NIGHT SCAN LITE Instructions Manual

Mobile lighting tower
Table of Contents

Advertisement

Functional Characteristic
Fully Extended Height
Fully Nested Height
Payload Weight Capacity
Payload Sail Area Capacity
Approximate Weight
(Includes HHRC and Junction Box)
Footprint
Mast Type
Emergency Operation
Frame Material
Mast Control Input Power
Mast Control System Amp Draw Including Inrush
Payload Input Power Through WB Controls
Payload Current Through WB Controls
Operating Temperature Range
Storage Temperature Range
Survival Wind Speed
(Payload Total Sail Area = 0.28 sq. m (3 sq. ft.); CD = 1.5)
Deployment Wind Speed Maximum
Maximum Deployment Angle
Maximum Altitude Above Sea Level
Approximate Mast Extension Time
Approximate Mast Retraction Time
Strobe Light Option
Camera Option
Airborn Noise Emissions
(measured according to EN ISO 3744:2010)
* Notes:
System weight varies based on the Payload. Capacity includes a 125% NFPA Safety Factor.
Dimensions and specifications are provided for reference only and are not intended for vehicle design
purposes.
Specifications may be subject to change without notice.
TP-5554501-B
May 2019
I
NSTRUCTIONS FOR

Table 1-4 Inflexion HD (No RCP/No Lights)

(Powered, 28 VDC)
(Powered, 28 VDC)
Original Instructions
N
S
L
IGHT
CAN
Specification*
2,000 mm (78.7 inches)
338 mm (13.3 inches)
36 kg (80 lb.) total
0.28 square meters (3.0 square feet)
56.7 kg (125 lb.)
1345 x 570 mm (53 x 22.4 inches)
Electro-Mechanical
Manual
Steel
20 – 30 VDC
< 20 Amps
20 – 30 VDC
< 40 Amps (20A per side)
-20 to 70°C (-4 to 158°F)
-40 to 70°C (-40 to 158°F)
160 km/h (100 mph)
92 km/h (57 mph)
±10° (17.6% Grade)
4572 meters (15,000 feet)
< 15 Seconds
< 15 Seconds
Yes
Yes
A-weighted sound pressure level: 57.1dB(A)
C-weighted instantaneous pres level: 79.7 dB
A-weighted sound power level: 75.2 dB(A)
& I
HD
ITE
NFLEXION
1-9