Cycle Input (Heat Control Only); Process Monitoring Status; Process Log Transfer; Process Data Filter - Husky Altanium Delta5 User Manual

Table of Contents

Advertisement

User Guide

12.4.3.3 Cycle Input (Heat Control Only)

Cycle Input supplies a start or end of cycle signal from the injection molding machine. This
input can be configured as the trigger to log process data on Altanium systems configured
for heats control only.
When this input is selected for use, the controller looks for a rising edge to trigger the start or
end of a cycle.
NOTE:
This feature can be enabled or disabled when you select or deselect the 'In Use' check-box in
the Cycle Input line on the Heats Page 1 tab of the Digital Inputs screen. Refer to
Section

12.4.4 Process Monitoring Status

The process monitoring Setup screen lets you see the controller's monitoring status. In the
Process Monitoring Status area of the screen, the information that follows is shown:

12.4.5 Process Log Transfer

The Process Log Transfer area of the monitoring Setup screen lets you select the quantity of
saved data and where to save it. You can select to save the Entire Log or by a Time Range. If
you select the Time Range option, the Starts and Stop time field are available for you to set
those values.
The Process Log Oldest Date and Log Filename fields are shown for information only.
Touch the Transfer button to navigate to the location where the Process Log is stored.

12.4.6 Process Data Filter

The Process Data Filter lets you filter which process variables are shown on the Trend and
History Plot screens, and saved in the Process Log. The selections are:
The default is the Current Mold Setup (when the controller is first started).
Cycle Input (Heat Control Only)
This should be connected to a cyclical signal (the signal goes HIGH to LOW during
each injection cycle)
13.1.3.
Data Collection Mode - shows the "Collecting" or "Not Collecting" status
Cycle Time - shows the actual cycle time for the data collection
Controller Cycle Active - an indicator that shows the cycle operation is active
Current Mold
Current Mold Setup
All (available data)
v 1.0 — February 2020
Data Recording
175