7. LW3 Programmers' Reference
7.4. System Commands
7.4.1. Query the Product Name
The name of the product is a read-only parameter and cannot be modified.
Command and Response
#producttype
ç GET·/.ProductName
pr·/.ProductName=<product_name>
æ
Example
ç GET /.ProductName
æ pr /.ProductName=UMX-HDMI-140
7.4.2. Set the Device Label
ATTENTION!
The device label can be changed to a custom text in the
writable parameter is not the same as the ProductName parameter.
Command and Response
#label #devicelabel
SET·/MANAGEMENT/UID/DeviceLabel=<custom_name>
ç
pw·/MANAGEMENT/UID/DeviceLabel=<custom_name>
æ
The Device Label can be 39 character length and ASCII characters are allowed. Longer names are truncated.
Example
ç SET /MANAGEMENT/UID.DeviceLabel=UMX-HDMI_Huddle_room
æ pw /MANAGEMENT/UID.DeviceLabel=UMX-HDMI_Huddle_room
7.4.3. Query the Serial Number
Command and Response
#serialnumber
ç GET·/.SerialNumber
pr·/.SerialNumber=<serial_numberr>
æ
Example
ç GET /.SerialNumber
æ pr /.SerialNumber=87654321
UMX-HDMI-140 series– User's Manual
Status
tab of the LDC software. This
Applied firmware package: v1.2.0 | LDC software: v2.4.1b7
7.4.4. Query the Firmware Version
Command and Response
#firmwareversion
ç GET·/SYS/MB.FirmwareVersion
pr·/SYS/MB.FirmwareVersion=<firmware_version>
æ
Example
ç GET /SYS/MB.FirmwareVersion
æ pr /SYS/MB.FirmwareVersion=1.2.0b8 r45
7.4.5. Resetting the Device
The switcher can be restarted – the current connections (LAN, RS-232) will be terminated.
Command and Response
#reset #reboot #restart
ç CALL·/SYS:reset()
æ mO·/SYS:reset=
Example
ç CALL /SYS:reset()
æ mO /SYS:reset=
7.4.6. Restore the Factory Default Settings
Command and Response
#factory
ç CALL·/SYS:factoryDefaults()
æ mO·/SYS:factoryDefaults=
Example
æ CALL /SYS:factoryDefaults()
æ mO /SYS:factoryDefaults=
The device is restarted, current connections are terminated, and the default settings are restored. See the
complete list in the
Factory Default Settings
section.
76