7. LW3 Programmers' Reference
7.8.10. Apply Network Settings
Calling the method results all network settings are applied in the device.
ATTENTION!
The command is always requires as the last step for applying the modified network settings.
Command and Response
ç CALL·/MANAGEMENT/NETWORK:ApplySettings()
æ mO·/MANAGEMENT/NETWORK:ApplySettings
Example
ç CALL /MANAGEMENT/NETWORK:ApplySettings()
æ mO /MANAGEMENT/NETWORK:ApplySettings
7.9. RS-232 Port Configuration
7.9.1. Protocol Setting
Command and Response
SET·/MEDIA/UART/P1.ControlProtocol=<protocol>
ç
pw·/MEDIA/UART/P1.ControlProtocol=<protocol>
æ
Parameters
Parameter
Parameter description
Control protocol which is
<protocol>
applied on the selected port
Example
ç SET /MEDIA/UART/P1.ControlProtocol=1
æ pw /MEDIA/UART/P1.ControlProtocol=1
#serial #rs232 #rs-232 #protocol
Value
Parameter value
0
LW2 protocol
1
LW3 protocol
Applied firmware package: v1.2.0 | LDC software: v2.4.1b7
UMX-HDMI-140 series– User's Manual
7.9.2. RS-232 Operation Mode
Command and Response
SET·/MEDIA/UART/P1.Rs232Mode=<mode>
ç
pw·/MEDIA/UART/P1.Rs232Mode=<mode>
æ
Parameters
Identifier
Parameter description
<mode>
Example
ç SET /MEDIA/UART/P1.Rs232Mode=1
æ pw /MEDIA/UART/P1.Rs232Mode=1
7.9.3. BAUD Rate Setting
Command and Response
SET·/MEDIA/UART/P1.Baudrate=<baud_rate>
ç
pw·/MEDIA/UART/P1.Baudrate=<baud_rate>
æ
Parameters
Parameter
Parameter description
<baudrate>
BAUD rate value
Example
ç SET /MEDIA/UART/P1.Baudrate=2
æ pw /MEDIA/UART/P1.Baudrate=2
Value
0
Event Manager mode
Stopbits value
1
Control mode
2
Command injection mode
Value
0
4800
1
7200
2
9600
3
14400
4
19200
5
38400
6
57600
7
115200
89
Parameter value
Parameter value