7. LW3 Programmers' Reference
7.10.5. Query the Last Recognized Serial Message in String Format
The recognized data is stored in string, hex and hash format in a temporary storage. They are erased when
the Active Timeout elapsed.
TIPS AND TRICKS:

When these properties are set as a conditionin the Event Manager, and the same
strings follow each other, the action will be executed every time if the active timeout has been set properly.
Command and Response
ç GET·/MEDIA/UART/RECOGNIZER.ActiveRx
·
æ pr
/MEDIA/UART/RECOGNIZER.ActiveRx=<recognized _string>
Parameters
<recognized _string>
Max. 12 byte-long recognized data string.
Example
ç GET /MEDIA/UART/RECOGNIZER.ActiveRx
æ pr /MEDIA/UART/RECOGNIZER.ActiveRx=Login:
7.10.6. Query the Last Recognized Serial Message in Hex Format
The recognized data is stored in string, hex and hash format in a temporary storage. They are erased when
the Active Timeout elapsed.

TIPS AND TRICKS:
When these properties are set as a condition in the Event Manager, and the same
strings follow each other, the action will execute every occasion if the active timeout set properly.
Command and Response
ç GET·/MEDIA/UART/RECOGNIZER.ActiveRxHex
æ pr·/MEDIA/UART/RECOGNIZER.ActiveRxHex=
Parameters
<recognized _hex>
Recognized data in hex format.
Example
ç GET /MEDIA/UART/RECOGNIZER.ActiveRxHex
æ pr /MEDIA/UART/RECOGNIZER.ActiveRxHex= 4C6F67696E3A
<recognized _hex>
Applied firmware package: v1.2.0 | LDC software: v2.4.1b7
UMX-HDMI-140 series– User's Manual
7.10.7. Set the Active Timeout
This property is responsible for erasing the temporary storage (ActiveRx, ActiveRxHex, ActiveHash) after the
elapsing time. Default value is 50ms.
Command and Response
SET·/MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=<a_timeout>
ç
pw·/MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=<a_timeout>
æ
Parameters
<a_timeout>
Active timeout value (ms) between 0 and 255.
Example
ç SET /MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=255
æ pw /MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=255
7.11. Infrared Port Configuration

INFO:
Infrared input and output port numbering can be found in the
7.11.1. Enable Command Injection Mode
Command and Response
#infra #infrared #ir
SET·/MEDIA/IR/<ir_port>.CommandInjectionEnable=<ci_status>
ç
pw·/MEDIA/IR/<ir_port>.CommandInjectionEnable=<ci_status>
æ
Parameters
Parameter
<logical_value>
Example
ç SET /MEDIA/IR/S1.CommandInjectionEnable=true
æ pw /MEDIA/IR/S1.CommandInjectionEnable=true
7.11.2. Change Command Injection Port Number
Command and Response
SET·/MEDIA/IR/<in|out>.CommandInjectionPort=<port_no>
ç
pw·/MEDIA/IR/<in|out>.CommandInjectionPort=<port_no>
æ
Example
ç SET /MEDIA/IR/S1.CommandInjectionPort=9001
æ pw /MEDIA/IR/S1.CommandInjectionPort=9001
Input/Output Port Numbering
Parameter description
Value
true
Command injection is enabled.
Command injection setting
false
Command injection is disabled.
92
section.
Explanation

Advertisement