7. LW3 Programmers' Reference
7.7. System Commands
7.7.1. Query the Product Name
The name of the product is a read-only parameter and cannot be modified.
Command format:
GET●/.ProductName
Response format:
pr●/.ProductName=<Product_name>
Example:
˃
GET /.ProductName
˂
pr /.ProductName=MMX8x4-HT420M
7.7.2. Query the Device Label
Command format:
GET●/MANAGEMENT/UID.DeviceLabel
Response format:
pr●/MANAGEMENT/UID.DeviceLabel=<Custom_name>
The Device Label can be 39 character length and ASCII characters are allowed. Longer names will be
truncated.
Example:
˃
GET /MANAGEMENT/UID.DeviceLabel
˂
pw /MANAGEMENT/UID.DeviceLabel=MMX8x4-HT420M
7.7.3. Set the Device Label
ATTENTION! The device label can be changed to a custom text which is displayed in many windows of
the LDC. This writable parameter is not the same as the ProductName parameter.
Command format:
SET●/MANAGEMENT/UID/DeviceLabel=<Custom_name>
Response format:
pw●/MANAGEMENT/UID/DeviceLabel=<Custom_name>
The Device Label can be 39 character length and ASCII characters are allowed. Longer names will be
truncated.
Example:
˃
SET /MANAGEMENT/UID.DeviceLabel=MMX_Control_room
˂
pw /MANAGEMENT/UID.DeviceLabel=MMX_Control_room
MMX8x4-HT series – User's Manual
7.7.4. Query the Serial Number
Command format:
GET●/.SerialNumber
Response format:
pr●/.SerialNumber=<serial_nr>
Example:
˃
GET /.SerialNumber
˂
pr /.SerialNumber=00005484
7.7.5. Resetting the Matrix
The matrix can be restarted – the current connections (LAN, RS-232) will be terminated.
Command format:
CALL●/SYS:reset()
Response format:
mO●/SYS:reset=
Example:
˃
CALL /SYS:reset()
˂
mO /SYS:reset=
7.7.6. Restore the Factory Default Settings
Command format:
CALL●/SYS:factoryDefaults()
Response format:
mO●/SYS:factoryDefaults=
Example:
˃
CALL /SYS:factoryDefaults()
˂
mO /SYS:factoryDefaults=
The device is restarted, current connections are terminated, and the default settings are restored. See the
complete list in
Factory Default Settings
section.