7.9.4. Databits Setting
Command and Response
SET·/MEDIA/UART/P1.DataBits=<databits>
ç
pw·/MEDIA/UART/P1.DataBits=<databits>
æ
Parameters
Parameter
Parameter description
<databits>
Databits value
Example
ç SET /MEDIA/UART/P1.DataBits=8
æ pw /MEDIA/UART/P1.DataBits=8
7.9.5. Stopbits Setting
Command and Response
SET·/MEDIA/UART/P1.StopBits=<stopbits>
ç
pw·/MEDIA/UART/P1.StopBits=<stopbits>
æ
Parameters
Parameter
Parameter description
<stopbits>
Stopbits value
Example
ç SET /MEDIA/UART/P1.StopBits=0
æ pw /MEDIA/UART/P1.StopBits=0
Value
Parameter value
8
8
9
9
Value
Parameter value
0
1
1
1,5
2
2
Applied firmware package: v1.2.0 | LDC software: v2.4.1b7
UMX-HDMI-140 series– User's Manual
7.9.6. Parity Setting
Command and Response
SET·/MEDIA/UART/P1.Parity=<parity>
ç
pw·/MEDIA/UART/P1.Parity=<parity>
æ
Parameters
Parameter
Parameter description
<parity>
Example
ç SET /MEDIA/UART/P1.Parity=0
æ pw /MEDIA/UART/P1.Parity=0
7.9.7. Command Injection Mode
Command and Response
#commandinjection
SET·/MEDIA/UART/P1.CommandInjectionEnable=<logical_value>
ç
pw·/MEDIA/UART/P1.CommandInjectionEnable=<logical_value>
æ
Parameters
Parameter
Parameter description

Command injection mode

<logical_value>
Example
ç SET /MEDIA/UART/P1.CommandInjectionEnable=true
æ pw /MEDIA/UART/P1.CommandInjectionEnable=true

INFO:
The
Command
/MEDIA/UART/P1.CommandInjectionStatus.
Value
0
None

Parity setting

1
Odd
2
Even
Value
true
Command injection mode is enabled.
status
false
Command injection mode is disabled.