5. Software Control - Lightware Device Controller
5.7.4. Creating an EDID - Easy EDID Creator
Since above mentioned Advanced EDID Editor needs more complex knowledge about EDID,
Lightware introduced a wizard-like interface for fast and easy EDID creation. With Easy EDID
Creator it is possible to create custom EDIDs in four simple steps. By clicking on the Create button below
Source panel, Easy EDID Creator is opened in a new window.
EDID Creator Window
Applied firmware package: v1.2.0 | LDC software: v2.4.1b7
UMX-HDMI-140 series– User's Manual
5.8. Control Menu
5.8.1. RS-232
The following settings and functions are available on the local RS-232 port:
▪
Operation mode: Control, Command Injection, or Event Manager (for more details about serial
interface modes see the
▪
Baud rate: 4800, 7200, 9600, 14400, 19200, 38400, 57600, 115200;
Data bits: 8 or 9;
▪
▪
Parity: None, Odd, or Even;
▪
Stop bits: 1, 1.5, or 2;
▪
Command injection: enable or disable;
▪
Command injection port number;
▪
Control protocol: LW2 or LW3;
▪
Message Recognizer
▪
Message sending via serial port;
▪
Reloading factory defaults (see factory default settings in the
RS-232 tab in Control menu
#serial #rs232 #rs-232 #protocol
Serial Interface
section);
#commandinjection
Factory Default Settings
44
section).