7. LW3 Programmers' Reference
7.13.2. Sending a CEC Command in Text Format
Command and Response
ç CALL·/MEDIA/CEC/<port>:send(<command>)
æ mO·/MEDIA/CEC/<port>:send
Parameters
The followings are accepted as <command>:
image_view_on
standby
down
left
contents_menu
favorite_menu
number_1
number_2
number_6
number_7
enter
clear
input_select
display_info
volume_up
volume_down
play
stop
fast_forward
eject
stop_record
pause_record
select_media_1
select_media_2
power_toggle
power_on
f2
f3
Example
ç CALL /MEDIA/CEC/O1:send(power_on)
æ mO /MEDIA/CEC/O1:send
7.13.3. Sending a CEC Command in Hexadecimal Format
Command and Response
ç CALL·/MEDIA/CEC/<port>:sendHex(<hex_code>)
æ mO·/MEDIA/CEC/<port>:sendHex
Parameters
<hex_code>
Accepted command is max. 30 character long (15 byte) in hexadecimal format.
Example
ç CALL /MEDIA/CEC/I1:sendHex(8700E091)
æ mO /MEDIA/CEC/I1:sendHex
ok
back
up
right
root_menu
setup_menu
media_top_menu
media_context_menu number_0
number_3
number_4
number_5
number_8
number_9
dot
channel_up
channel_down
sound_select
power_legacy
page_up
page_down
mute_toggle
mute
unmute
pause
record
rewind
skip_forward
skip_backward
3d_mode
play_forward
play_reverse
select_next_media
select_media_3
select_media_4
select_media_5
power_off
stop_function
f1
f4
Applied firmware package: v1.2.0 | LDC software: v2.4.1b7
UMX-HDMI-140 series– User's Manual
7.14. EDID Management
Parameters
Parameter
<emulated>
The emulated EDID memory of the desired input port. Example: E1.
<dynamic>
Dynamic EDID memory index. Example: D1
<user>
User EDID memory index. Example: U1
<factory>
Factory EDID memory index. Example: F1
See the list of all factory EDID tracks in the
7.14.1. Query the Emulated EDIDs
Command and Response
#edid
ç GET·/EDID.EdidStatus
pr·/EDID.EdidStatus=<dynamic|user|factory>:<emulated>;...;<dynamic|user|factory>:<emulated>
æ
Example
ç GET /EDID.EdidStatus
æ pr /EDID.EdidStatus=D1:E1;F47:E2
Emulated EDID memory for input port is listed with the EDID number that is currently emulated on the input.
7.14.2. Query the Validity of a Dynamic EDID
Command and Response
ç GET·/EDID/D/<dynamic>.Validity
pr·/EDID/D/<dynamic>.Validity=<logical_value>
æ
Parameters
The
<logical_value>
can be true or false.
Example
ç GET /EDID/D/D1.Validity
æ pr /EDID/D/D1.Validity=true
Description
Factory EDID List
section.
97