Number of Modules Per Series 90-30 PLC System

The following table lists the maximum number of each type of I/O and option modules that can be
installed in a Series 90-30 PLC system. The number of modules that can be installed in a system
depends on several factors, including available references for each CPU model, the current rating
for each module to be installed in the system, and other installed modules. Before installing
modules in a baseplate, verify that the total current rating of all of those modules does not exceed
the power rating of the power supply.
Table 12-2. Maximum Number of Modules Per System
Input and Output, Discrete
Input Module, Analog , 4-Channel
Input Module, Analog, 16-Channel
Output Module (Voltage), Analog, 2-Channel
Output Module (Current), Analog, 2-Channel
Output Module, Analog, 8-Channel
Combination Input/Output Module, Analog
4-Ch In/2-Ch Out
Programmable Coprocessor Module
Alphanumeric Display Coprocessor Module
Communications Control Module
State Logic Processor Module
Genius Communications Module (1)
Enhanced Genius Communications Module (1)
High Speed Counter
I/O Link Interface Module
I/O Processor Module
Genius Bus Controller (2)
Ethernet Interface Module
Motion Mate APM300 Module
Motion Mate DSM302 Module
Motion Mate DSM314 Module
Temperature Control Module
Power Transducer Module
(1) The Enhanced Genius Communications Module and the Genius Communications Module cannot be installed in
the same PLC baseplate; however, both modules can be present on the same bus.
(2) Refer to GFK-1034, Series 90-30 Genius Bus Controller User's Manual for details.
GFK-0356Q
Chapter 12 System Design
Module Type
System Design and Layout
CPU
Model 311/313/323
Model 331/340/341
5 (5-slot baseplate)
49 (331/340/341)
10 (10-slot baseplate)
5 (5-slot baseplate)
40
8 (10-slot baseplate)
4
8 (Model 331)
12 (Model 340/341)
5 (5-slot baseplate)
16 (Model 331)
6 (10-slot baseplate)
30 (Model 340/341)
3 (5-slot baseplate)
15 (Model 331)
3 (10-slot baseplate)
15 (Model 340/341)
4
8 (Model 331)
32 (Model 340/341)
5 (5-slot baseplate)
21 (Model 331/40/341)
10 (10-slot baseplate)
n/a
4
n/a
4
n/a
9
n/a
Refer to the State Logic User's Guide, GFK-0726.
1
1
2
2
4 (5/10-slot baseplate)
8 (Model 331)
32 (Model 340/341)
5 (5/10-slot baseplate)
49
2 (5-slot baseplate)
8 (Model 331)
4 (10-slot baseplate)
16 (Model 340/341)
8
8
Refer to the Series 90-30 TCP/IP Ethernet Communications User's Manual,
GFK-1084 for details.
Refer to the Motion Mate APM300 User's Manuals, GFK-0840 or GFK-0781
for details.
Refer to the Motion Mate DSM302 User's Manual, GFK-1464 , for details.
Refer to the Motion Mate DSM314 User's Manual, GFK-1742 , for details
Refer to the Temperature Control User's Manual, GFK-1466 for details
Refer to the Power Transducer Module User's Manual, GFK-1734, for details
CPU
CPU
Model 350 - 364
79
64
51
48
24
79
79
4
4
9
1
2
79
79
64
8
12-11
12