10
IC690CBL705
Workmaster II (PS/2) to PCM, ADC, CMM Cable
Function of cable
This cable provides RTS-232 signal connections between the RS-232 port on a PCM, ADC, or
CMM module and a serial port on a Workmaster II or an IBM Personal System 2 (PS/2) or
equivalent Personal Computer.
Cable Specifications
Cable Length
Connectors
Cable Clamps
Cable Type
Wiring Diagram
Figure 10-9. PCM, ADC, or CMM to Workmaster II or PS/2 Serial Cable
10-16
Series 90-30 PLC Installation and Hardware Manual – August 2002
10 feet (3 meters)
25-pin male, D-subminiature type, AMP 205208-1, or equivalent
PCM/ADC/CMM Side
25-pin female, D-subminiature type, AMP 205207-1, or equivalent
Programmer Side
25-pin
AMP 207908-7 or equivalent
Six conductor, overall shield, non-paired AWG #24 (.21 mm
equivalent
WORKMASTER II
AND
IBM PS/2
25- PIN
MALE
PIN
PIN
TD
2
3
RD
3
2
RTS
4
5
CTS
5
20
DCD
8
8
DTR
20
1
GND
7
7
25- PIN
25- PIN
FEMALE
MALE
2
), Belden 9536 or
RD
TD
CTS
DTR
PCM
DCD
SHLD
GND