COMMAND
LGCLOADCORR
LGCLOADSCALE
LGCSAVECORR
LGCSAVESCALE
OUTPULGCFRQ<frequency part of
correction table>
OUTPULGCPWR<power part of correction
table>
POWP1
POWP2
PPBLANKON
PPBLANKOFF
PPBLANK?
PPCOUPLEON
PPCOUPLEOFF
PPCOUPLE?
PPDETALWAYS
PPDETNEVER
Menus & Commands
New GPIB Commands
EQUIVALENT SOFTKEY
No softkey equivalent
No softkey equivalent
No softkey equivalent
No softkey equivalent
No softkey equivalent
No softkey equivalent
STIMULUS [MENU] {POWER MENU}
{PORT1 POWER}
STIMULUS [MENU] {POWER MENU}
{PORT2 POWER}
[SYSTEM] {MORE} {RF POWER CONFIG}
{MORE} {BLANKING ON}
[SYSTEM] {MORE} {RF POWER CONFIG}
{MORE} {BLANKING OFF}
No softkey equivalent
STIMULUS [MENU] {POWER MENU}
{COUPLE PORTS}
STIMULUS [MENU] {POWER MENU}
{UNCOUPLE PORTS}
No softkey equivalent
[SYSTEM] {MORE} {RF POWER CONFIG}
{MORE} {DET UNL ALWAYS}
[SYSTEM] {MORE} {RF POWER CONFIG}
{MORE} {DET UNL NEVER}
7-44 8510XF Network Analyzer Systems
FUNCTION
Used by Agilent service engineers to load
conversion loss calibration data from the test
set EEPROM to the memory of the 8510C.
Used by Agilent service engineers to load
detector gain calibration data from the test
set EEPROM to the memory of the 8510C.
Used by Agilent service engineers to save
conversion loss calibration data from the
memory of the 8510C to the test set
EEPROM.
Used by Agilent service engineers to save
detector gain calibration data from the
memory of the 8510C to the test set
EEPROM.
Used by Agilent service engineers to read
values from the frequency part of the
correction table in the memory of the
8510XF.
Used by Agilent service engineers to read
values from the power part of the correction
table in the memory of the 8510XF.
Port 1 power (level in dBm can be specified)
Port 2 power (level in dBm can be specified)
Enables port power blanking during
frequency transitions or port drive transitions.
Disables port power blanking during
frequency transitions or port drive transitions.
Queries the status of port power blanking
(0 for OFF, 1 for ON).
Couples the Port 2 power setting to the
Port 1 Power setting.
Uncouples the Port 2 power setting from the
Port 1 power setting
Queries the status of port power coupling
(0 for OFF, 1 for ON).
Enables detection of "unleveled" errors,
during every sweep.
Disables detection of "unleveled" errors while
sweeping.