Cable and fiber installation
............................................................................................................................................................................................................................................................

100/1000BASE-X optical fiber cable installation

Description
This section describes how to route the 100/1000BASE-X optical fiber cables from the
interconnecting equipment (for example, an LGX
100/1000BASE-X optical ports. The LNW70, LNW170, LNW63 and LNW64 single
mode or multimode fiber can be used depending on the SFP provided with the work order.
Note:
placed in a protective tube or channel, such as PVC tubing, or PANDUIT cable
channel, when running the cable from the Alcatel-Lucent 1850 TSS-60 to the cable
rack. The fibers should be placed in the cable rack in a protective channel with nothing
on top of them. Cable ties should NOT be used with the optical fiber cables.
Unterminated optical connectors may emit laser radiation. Do not view an unterminated
optical connector with optical instruments.
Invisible laser radiation exists when unterminated. Avoid direct exposure of the eyes to
the beam.
Note:
ensure that they are clean. See
cleaning procedures.
............................................................................................................................................................................................................................................................
365-372-603R2.0
Issue 1 January 2009
The optical fiber cable is fragile and must be protected. The fibers should be
WARNING
Laser hazard
WARNING
Laser hazard
Prior to connecting the optical fiber cables, the fibers should be examined to
100/1000BASE-X optical fiber cable installation
®
optical fiber distributing frame) to the
Appendix B, "Fiber cleaning"
for recommended
3 - 7 1