Network turn-up and testing
............................................................................................................................................................................................................................................................
Qty.
1
1
1
2 or 3
1
1
............................................................................................................................................................................................................................................................
II I- 2
Description
DS1 Error Rate Test Set
ITE-7113
DS3 Error Rate Test Set
ITE-7113
Optical Test Set (Optional)
LC-type Optical Fiber
Jumper ITE-7169
(108918269)
15-dB LC-type LBO
ITE-7196 (108279480)
Noyes OFS 300-200X
Optical Fiber Scope
ITE-7129
2.5mm Universal adapter
cap ITE-7129 D1
1.25mm Universal adapter
cap ITE-7129 D2
Noyes VFS-1 ITE-7187
1
Video Fiber Scope
Individual presaturated
alcohol wipes ITE-7136
CLETOP Cleaning
Cassette ITE-7137
Comments
A DS1 error rate test set is required for testing of DS1
cabling. A T-BERD 2209 or equivalent is
recommended.
A DS3 error rate test set is required for testing of DS3
cabling. A T-BERD 209 or equivalent is
recommended.
A Optical test set is required for testing of low speed
optics OC3/12/48. An Omniber 718 or equivalent is
recommended.
Two optical fiber jumpers with LC type connectors are
required to optically loop the Alcatel-Lucent 1850
TSS-60 shelf for test purposes. In addition, for shelves
containing optical circuit packs in any of the function
unit slots, a single optical fiber jumper is required for
testing of the individual ports.
LBOs are only required when optically looping the
Alcatel-Lucent 1850 TSS-60 shelves containing
optical circuit packs in any of the function unit slots; a
single 15-dB LBO is required for testing of the
individual ports
This equipment may not be necessary at all locations.
It is to be used when the ports need to be verified for
cleanliness. If care is exercised when cleaning fibers,
the optical fiber scope may not be needed
For use with the Noyes OFS 300-200X Optical Fiber
Scope
This equipment may not be necessary at all locations.
It is to be used when the ports need to be verified for
cleanliness. If care is exercised when cleaning fibers,
the video scope may not be needed
99% pure isopropyl alcohol
Type A Reel
365-372-603R2.0
Issue 1 January 2009