Connecting adjacent network elements
............................................................................................................................................................................................................................................................

Automatic protection switching test

Description
This section provides the procedures for verifying the Alcatel-Lucent 1850 TSS-60 shelf
automatic and manual protection switching.
Note the following:
These tests do NOT simulate circuit pack failures.
A properly grounded wrist strap must always be worn while handling circuit packs.
Prior to performing each test, the shelf under test must be clear of all alarms (that is,
only green LEDs are lighted).
Main OLIU switch test
........................................................................................................................................................................................................................
1
In order to perform path switching, enter an STS-1 add/drop cross-connection between an
equipped Function Unit and the Main OLIU. Select
Cross-Connections...
cross-connection.
........................................................................................................................................................................................................................
2
Select
........................................................................................................................................................................................................................
3
Under Path Protection choose
........................................................................................................................................................................................................................
4
Note the Active Path (m1 or m2).
........................................................................................................................................................................................................................
5
Disconnect the optical fiber connected to the IN port on the active path OLIU.
Result:
LED should flash on the OLIU.
........................................................................................................................................................................................................................
6
Refresh
Click
........................................................................................................................................................................................................................
7
Verify the Active Path has changed (from m1 to m2 or m2 to m1).
............................................................................................................................................................................................................................................................
365-372-603R2.0
Issue 1 January 2009
and use the
View -> Protection...
The MN and then MJ alarm LED should light on the SYSCTL and the FAULT
View Protection
in the
Cross-Connection Wizard
Path m1-1-1
and click
window.
Automatic protection switching test
Configuration ->
to enter an add/drop
Select
.
7 - 1 3