Stand-alone installation testing
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
7
Verify that the port you are connected to matches the one listed in the aid of the FE-LAN
LOS alarm output.
........................................................................................................................................................................................................................
8
Select
........................................................................................................................................................................................................................
9
Yes
Click
........................................................................................................................................................................................................................
10
The flashing fault LED on the LNW74 or LNW66 will clear.
........................................................................................................................................................................................................................
11
Connect the RJ45 cable to the next jack on the RJ45 patch panel and repeat starting at
4
until all connected jacks have been tested.
E
O
N D
........................................................................................................................................................
Ethernet port wiring verification testing
Note:
complete for LNW74 packs!
........................................................................................................................................................................................................................
1
If not still connected serially from the last procedure then, connect the Front CIT cable
between the PC and the CIT/RS-232 jack of System Controller and login to the shelf using
the serial connection.
........................................................................................................................................................................................................................
2
Select
........................................................................................................................................................................................................................
3
Choose the LNW66 that is being tested.
........................................................................................................................................................................................................................
4
Select
Click
........................................................................................................................................................................................................................
5
Virtual Switch ID: 1
Enter
............................................................................................................................................................................................................................................................
365-372-603R2.0
Issue 1 January 2009
Configuration -> Update System -> Update All.
to issue the command.
S
F
T E P S
Continue with the following section only for LNW66 circuit packs. Testing is
Configuration -> Data -> Create Virtual Switch
.
.
LNW74 and LNW66 testing
..
.
Step
6 - 2 5