Cable and fiber installation
............................................................................................................................................................................................................................................................

DS1/EI cable installation

Description
This section describes how to connect the DS1/E1 transmission cables for function group
D or G, to the shelf, route the cables out of the bay and connect the cables to the DSX.
Perform this procedure if DS1/E1 cables are required.
Note:
an extension of the Alcatel-Lucent 1850 TSS-60 backplane connections. Thus the IN
on the Alcatel-Lucent 1850 TSS-60 backplane connects to the IN of the DSX and the
OUT of the Alcatel-Lucent 1850 TSS-60 backplane connects to the OUT of the DSX
respectively.
The cables have connectors at the Alcatel-Lucent 1850 TSS-60 shelf end and must be
wire-wrapped at the DSX end. A total of two function groups fully cabled will have 112
DS1/E1 drop capacity.
Note:
the LNW39 DS1/DS3/16/3 combo card in slot A/B. Instructions for cabling slot A/B
are provided in
Note:
frame ground through the backplane. Alcatel-Lucent recommends that the shield at
both ends of the DS1/E1 cable be grounded. Ground at the DSX end per office
requirements.
Procedure
Proceed as follows:
........................................................................................................................................................................................................................
1
Refer to the engineering job specification. Obtain the DS1/E1 cables per
"DS1/E1 cable assemblies" (p. 3-11)
used. Label the cables, indicating bay, shelf, function group (D or G) and direction (IN or
OUT of the bay) at each end.
........................................................................................................................................................................................................................
2
Connect the function group cables at the Alcatel-Lucent 1850 TSS-60 end, carefully
matching the correct connector with the appropriate backplane connectors as shown in
Figure 3-2, "DS1/E1 cable connectors" (p.
Note:
Do not overtighten.
............................................................................................................................................................................................................................................................
3 - 8
When cabling the Alcatel-Lucent 1850 TSS-60 to a DSX, the DSX becomes
The 112 DS1 drops do not include the 16 port DS1 drop available when using
"DS1 and DS3 hybrid cable installation" (p.
The connectorized cable end is grounded to the Alcatel-Lucent 1850 TSS-60
DS1/E1 cable retaining screws must be tightened to a maximum of 6.5 in-lb.
and note the function group where each cable will be
3-9).
DS1/EI cable installation
3-35).
Table 3-2,
365-372-603R2.0
Issue 1 January 2009