Alcatel-Lucent 1850 TSS-60 Installation And System Turn-Up Manual page 268

Transport service switch
Table of Contents

Advertisement

Connecting adjacent network elements
............................................................................................................................................................................................................................................................
Fiber installation
Description
This section is used to verify proper fiber connections between Alcatel-Lucent 1850
Transport Service Switch 60 (TSS-60) nodes.
Prerequisite
The following is a list of items to verify before beginning tests in this section.
A properly grounded ESD wrist strap MUST be worn when handling circuit packs.
Unterminated optical connectors may emit laser radiation. Do not view beam with
optical instruments.
Procedure
The following procedures are performed at each end of the optical span being tested.
........................................................................................................................................................................................................................
1
Verify that the office alarm cable to J13 (ALM) on the backplane of the Alcatel-Lucent
1850 TSS-60 shelf is disconnected. If the shelf to be tested is part of a multiple shelf bay
arrangement, the office alarm cable connects to shelf 1.
........................................................................................................................................................................................................................
2
Enter the shelf TID per the customer order or use ALU-TSS-60-1 and ALU-TSS-60-2 as
defaults.
............................................................................................................................................................................................................................................................
7 - 4
Two people are required to perform the end-to-end turn up in this section (one at
each adjacent node).
The Alcatel-Lucent 1850 TSS-60 Main OLIUs should be optically looped from the
previous section. Verify that the Alcatel-Lucent 1850 TSS-60 shelf is clear of all
alarms (only green LEDs are lighted) prior to and after completing this test.
®
WaveStar
CIT is still connected to the Alcatel-Lucent 1850 TSS-60 and the GUI
is running.
The office alarm cable will remain disconnected during this procedure.
A properly grounded ESD wrist strap must always be worn while handling circuit
packs.
CAUTION
ESD hazard
WARNING
Laser hazard
Fiber installation
365-372-603R2.0
Issue 1 January 2009

Advertisement