Alcatel-Lucent 1850 TSS-60 Installation And System Turn-Up Manual page 240

Transport service switch
Table of Contents

Advertisement

Stand-alone installation testing
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
14
Click on
........................................................................................................................................................................................................................
15
Select
........................................................................................................................................................................................................................
16
Select
Click
Result:
that was just entered.
........................................................................................................................................................................................................................
17
Unseat one of the LNW7, LNW8, LNW111, LNW16, LNW18, LNW20, LNW19B,
LNW112, LNW801 or LNW39/LNW391 circuit packs from the function group being
used.
Result:
Note:
time is 2 seconds.
........................................................................................................................................................................................................................
18
Press the ACO pushbutton on the SYSCTL.
Result:
........................................................................................................................................................................................................................
19
Disconnect one of the optical fiber jumpers from the OUT port of the OLIU circuit pack in
the M1 slot.
Result:
........................................................................................................................................................................................................................
20
Press the ACO pushbutton on the SYSCTL.
Result:
The MJ audible alarm should clear.
........................................................................................................................................................................................................................
21
Unseat the second circuit pack from the same function group pair as the circuit pack
removed in
Result:
............................................................................................................................................................................................................................................................
6 - 4 6
View -> Cross-Connections
Shelf
.
to issue the command.
The View Cross-Connection window will open displaying the cross-connect
Activated office alarms: MN visual, MN audible.
Alarms will not be activated until the alarm delay time has passed. The default
Activated office alarm: MN visual. The MN audible alarm clears.
Activated office alarms: MJ visual, MJ audible.
Activated office alarm: MJ visual.
Step
17.
Activated office alarms: CR visual, CR audible.
.
Office alarm test
365-372-603R2.0
Issue 1 January 2009