PDW-HD1550
Drive log-
Description
ger
BRIDGE (IC700: BD-42 board) temperature alarm was detected.
BRIDGE (IC700: BD-42 board) temperature exceeded 80 degrees.
BRIDGE (IC700: BD-42 board) fan stop was detected.
No data can be read from the SPI-EEPROM (IC709: BD-42 board).
An SPI-EEPROM (IC709: BD-42 board) error was detected.
A BPI-FLASH (IC701: BD-42 board) data error was detected.
No data can be written to the BPI-FLASH (IC701: BD-42 board) during
firmware upgrade.
RTC (IC710: BD-42 board) read data error was detected.
Adjustment data cannot be read from the EEPROM in optical block
assembly Ch-A.
Hours meter data cannot be read from the EEPROM in optical block
assembly Ch-A.
Ch-A Disc Drive LSI (IC100: BD-42 board) cannot read adjustment
data from the SE EEPROM (IC3: SE-1004 board).
Ch-A Disc Drive LSI (IC100: BD-42 board) cannot read hours meter
data from the SE EEPROM (IC3: SE-1004 board).
Ch-A Disc Drive LSI (IC100: BD-42 board) detected a configuration
error of PERIPHERAL (IC600: BD-42 board).
Optical block assembly Ch-A cannot initialize PERIPHERAL device.
IL adjustment has not been completed in optical block assembly Ch-A.
No data can be written to the EEPROM in optical block assembly Ch-
A.
Ch-A Disc Drive LSI (IC100: BD-42 board) cannot write data to the SE
EEPROM (IC3: SE-1004 board).
A system error was detected in Ch-A Disc Drive LSI (IC100: BD-42
board).
Adjustment data cannot be read from the EEPROM in optical block
assembly Ch-B.
Hours meter data cannot be read from the EEPROM in optical block
assembly Ch-B.
Ch-B Disc Drive LSI (IC200: BD-42 board) cannot read adjustment
data from the SE EEPROM (IC3: SE-1004 board).
Ch-B Disc Drive LSI (IC200: BD-42 board) cannot read hours meter
data from the SE EEPROM (IC3: SE-1004 board).
Ch-B Disc Drive LSI (IC200: BD-42 board) detected a configuration
error of PERIPHERAL (IC600: BD-42 board).
Optical block assembly Ch-B cannot initialize PERIPHERAL device.
IL adjustment has not been completed in optical block assembly Ch-B.
No data can be written to the EEPROM in optical block assembly Ch-
B.
Ch-B Disc Drive LSI (IC200: BD-42 board) cannot write data to the SE
EEPROM (IC3: SE-1004 board).
A system error was detected in Ch-B Disc Drive LSI (IC200: BD-42
board).
2-8