4.
Perform the adjustment by rotating the [PUSH SET] knob so that a frequency counter reading satisfies the
specification.
Measurement Point: TP2802/HPR-55 board
Specification: 27.00000 ±0.00005 MHz
HPR-55 board (side B)
5.
Press the [MENU] button to return to the MENU screen.
6.
Press the [F1 (RETURN)] button.
7.
Select "A2F: NV-RAM CONTROL" by rotating the [PUSH SET] knob, and press the [PUSH SET] knob.
8.
Select "SAVE ALL ADJUST DATA" by rotating the [PUSH SET] knob, and press the [F5 (SAVE)] button to save
the adjustment data.