B.2
Connecting to the Target System
This section explains how to connect the target system.
First insert the S5U1C63000P6 board into the second upper slot of the ICE and the S5U1C6F016P2 board into the
top slot. Download the circuit data to the S5U1C63000P6 board before installing the S5U1C6F016P2 board if the
S5U1C63000P6 board does not include the correct circuit data. See Section B.3 for downloading circuit data.
DI AG
O FF
installing the S5u1C63000P6/6F016P2 board
Set the jig included with the ICE into position as
shown in Figure B.2.2. Using this jig as a lever, push
it toward the inside of the board evenly on the left and
right sides. After confirming that the board has been
firmly fitted into the internal slot of the ICE, remove
the jig.
Dismounting the S5u1C63000P6/6F016P2 board
Set the jig included with the ICE into position as
shown in Figure B.2.3. Using this jig as a lever, push
it toward the outside of the board evenly on the left
and right sides. After confirming that the board has
been dismounted from the backboard connector, pull
the board out of the ICE.
To connect the S5U1C63000P6 and S5U1C6F016P2 to the target system, use the I/O connecting cables supplied with
these boards. Take care when handling the connectors, since they conduct electrical power (V
S1C63003/004/008/016 TeChniCal Manual
(Rev. 1.1)
aPPenDiX B PeRiPheRal CiRCuiT BOaRDS FOR S1C6F016
LC 1
LC 2
6 3 0 0 0 h
S 5 u 1 C
O N
Figure B.
2.1 Installing the peripheral circuit boards to the ICE
Seiko epson Corporation
6
S5U1C6F016P2
Figure B.
2.2 Installing the board
Board
Figure B.
2.3 Dismounting the board
S5U1C63000P6
Board
= +3.3 V).
DD
aP-B-5