Appendix D Mask Data Creation Procedure; Mask Data Creation Flowchart; Function Option File Creation Procedure; Segment Option File Creation Procedure - Epson S1C63003 Technical Manual

Cmos 4-bit single chip microcontroller
Table of Contents

Advertisement

Appendix D Mask Data Creation Procedure

This chapter shows a procedure to create an S1C630 Series (S1C63003/004/008/016) mask data file (PAx) for sub-
mission to Seiko Epson. Use the appropriate device information definition file according to the model to be used.
Note: Before creating the mask data file, get the latest device information definition file package listed
below from our website.
S1C63003 device information definition file version 5.0 or later
S1C63004 device information definition file version 6.0 or later
S1C63008 device information definition file version 4.0 or later
S1C63016 device information definition file version 1.0 or later
D.1

Mask Data Creation Flowchart

D.2

Function Option File Creation Procedure

The following shows a procedure to create a function option file:
1. Launch the function option generator (winfog.exe).
2. Load the device information definition file (INI).
Select "Device INI select" from the "Tool (T)" menu or click the "Device INI select" button.
When the dialog box appears, select the folder and file (INI) for the target model.
*2
• Folder: 630xx
*2
• File:
630xx.INI
3. Set up information such as the output folder/file name.
Select "Setup (S)" from the "Tool (T)" menu or click the "Setup" button.
Enter the information required through the dialog box appeared.
4. Select options to be used.
5. Generate the function option files (FDC, FSA).
Select "Generate (G)" from the "Tool (T)" menu or click the "Generate" button.
The function option files will be generated.
D.3

Segment Option File Creation Procedure

The following shows a procedure to create a segment option file:
1. Launch the segment option generator (winsog.exe).
2. Load the device information definition file (INI).
Select "Device INI select" from the "Tool (T)" menu or click the "Device INI select" button.
When the dialog box appears, select the folder and file (INI) for the target model.
*2
• Folder: 630xx
*2
• File:
630xx.INI
S1C63003/004/008/016 TeChniCal Manual
(Rev. 1.1)
*1
Create function option file
(FDC)
Create segment option file
(SDC)
Create mask data file
(PAx)
Figure D.
1.1 Mask data creation flowchart
Seiko epson Corporation
aPPenDiX D MaSK DaTa CReaTiOn PROCeDuRe
See Section D.2.
See Section D.3.
See Section D.4.
aP-D-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

S1c63004S1c63008S1c63016

Table of Contents