aPPenDiX D MaSK DaTa CReaTiOn PROCeDuRe
3. Set up information such as the output folder/file name.
Select "Setup (S)" from the "Tool (T)" menu or click the "Setup" button.
Enter the information required through the dialog box appeared.
4. Load a segment assignment data file (SAD).
Select "Record (R) → Load (L)" from the "Fie (F)" menu or click the "Load" button.
When the dialog box appears, select the folder and file (SAD) for the target model.
*2
• Folder: 630xx
*2
• File:
630xx.SAD
Note: The area that allows configuration of segment assignment and output specification is restricted as
shown in Figure D.3.1. Assignment must be performed within the assignable area only.
Area that cannot be assigned (unavailable SEG terminals)
Fixed specification area
5. Segment assignment
Assign addresses/data bits to the assignable area according to the system design.
6. Generate the segment option files (SDC, SSA).
Select "Generate (G)" from the "Tool (T)" menu or click the "Generate" button.
The segment option files will be generated.
D.4
Mask Data File Creation Procedure
The following shows a procedure to create a mask data file:
1. Launch the mask data checker (winmdc.exe).
2. Load the device information definition file (INI).
Select "Device INI select" from the "Tool (T)" menu or click the "Device INI select" button.
When the dialog box appears, select the folder and file for the target model.
*2
• Folder: 630xx
*2
• File:
630xx.INI
aP-D-2
Figure D.
3.1 Sample segment assignment area
Seiko epson Corporation
Assignable area
S1C63003/004/008/016 TeChniCal Manual
(Rev. 1.1)