Epson S1C63003 Technical Manual page 82

Cmos 4-bit single chip microcontroller
Table of Contents

Advertisement

Direct LAP input (P01/P00)
Capture renewal flag CRNWF
SWD[3:0] reading
SWD[7:4] reading
SWD[11:8] reading
Data holding
1 Hz interrupt factor flag ISW1
Lap data carry-up request flag LCURF
Counter data
Figure 10.
Key mask
In stopwatch applications, some functions may be controlled by a combination of keys including direct RUN or
direct LAP. For instance, the RUN key can be used for other functions, such as reset and setting a watch, by press-
ing the RUN key with another key. In this case, the direct RUN function or direct LAP function must be invalid
so that it does not function. For this purpose, the key mask function is set so that it judges concurrence of input
keys and invalidates RUN and LAP functions. A combination of the key inputs for this judgment can be selected
using the DKM[2:0] register.
RUN or LAP inputs become invalid in the following status.
1. The RUN or LAP key is pressed when one or more keys that are included in the selected combination (here
in after referred to as mask) are held down.
2. The RUN or LAP key has been pressed when the mask is released.
RUN or LAP inputs become valid in the following status.
1. Either the RUN or LAP key is pressed independently if no other key is been held down.
2. Both the RUN and LAP keys are pressed at the same time if no other key is held down. (RUN and LAP
functions are effective.)
3. The RUN or LAP key is pressed if either is held down. (RUN and LAP functions are effective.)
4. Either the RUN or LAP key and the mask key are pressed at the same time if no other key is held down.
5. Both the RUN and LAP keys and the mask key are pressed at the same time if no other key is held down. (RUN
and LAP functions are effective.)
* Simultaneous key input is referred to as two or more key inputs are sampled at the same falling edge of 1,024
Hz clock.
S1C63003/004/008/016 TeChniCal Manual
(Rev. 1.1)
6.3 Timing for data holding and reading during direct LAP input
Table 10.
6.2 Key mask selection
DKM[2:0]
0H
1H
2H
3H
4H
5H
6H
7H
f
/32 (1,024 Hz)
OSC1
Direct RUN/LAP input
Key mask
valid
Figure 10.
6.4 Operation of key mask
Seiko epson Corporation
999
000
Mask key combination
None (at initial reset)
P02
P02, P03
P02, P03, P10
P10
P10, P11
P10, P11, P12
P10, P11, P12, P13
invalid
invalid
invalid
10 STOPWaTCh TiMeR
10-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

S1c63004S1c63008S1c63016