Zapi DUALACE2 NEW GENERATION User Manual page 34

Table of Contents

Advertisement

Pin
Type
A17
Input
A18
Output
A19
Input
A20
Input
A21
Output
NENC_R
A22
Input
A23
Input
A24
Input
A25
Output
A26
Output
A27
Output
A28
Output
A29
Output
A30
Output
A31
Output
A32
Input
Page 34/169
DUALACE2 NEW GENERATION (dual traction)
Name
Description
CHA_L
Channel A of the left-hand side incremental encoder.
If connected to A31 (CANH), it introduces the 120 Ohm
CANT
termination resistance between CANL and CANH.
CHB_L
Channel B of the left-hand side incremental encoder.
CHB_R
Channel B of the right-hand side incremental encoder.
Negative supply for the right-hand side encoder, the right-hand
side thermal sensor and potentiometers.
Analog input 4.
CPOT
The default function is as reference for the proportional
EVP
electrovalve.
NCAN
CAN bus negative reference. See paragraph 4.4.11
Positive supply for the high-side driver of pin PEB (A27). By
PIN
default, it is to be connected after the main contactor.
Driving output for the proportional electrovalve (driving to -B);
PWM current-controlled; 1.7 A maximum continuous current.
NEVP
Default function is as LOWERING valve.
Driving output for the line – or main – contactor (driving to -B);
NLC
PWM controlled; 2 A maximum continuous current.
Positive supply for the electromechanical brake and the
PEB
electrovalves. It is supplied by PIN (A24) through a high-side
driver.
Driving output for the right-hand side electromechanical brake
NEB_R
(driving to -B); PWM controlled; 3 A maximum continuous
current.
Driving output for the left-hand side electromechanical brake
NEB_L
(driving to -B); PWM controlled; 3 A maximum continuous
current.
CANL
Low-level CAN bus line.
CANH
High-level CAN bus line.
Analog input for the thermal sensor of the right-hand side
traction motor.
PTH_R
Internal pull-up is a 2 mA current source (max 5 V).
AFNZPxxx – DUALACE2 NEW GENERATION – User Manual

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DUALACE2 NEW GENERATION and is the answer not in the manual?

Questions and answers

Giraldo Rubio Lazo
January 28, 2025

Como comprobar el funcionamiento del controlador dualac2 sin display

1 comments:
Mr. Anderson
February 10, 2025

You can check the operation of the Zapi DUALACE2 NEW GENERATION controller without a display using the following methods:

1. Zapi Smart Console – Connect the Zapi Smart Console to the CAN bus to access diagnostics and parameter settings.
2. PC CAN Console – Use the PC CAN Console software to monitor and adjust controller settings.
3. Self-Diagnosis Feature – The controller performs self-diagnosis, and faults can be displayed using Zapi tools.
4. Alarm History Log – Check the log of alarms to review past faults and system behavior.
5. TESTER Function – Use the TESTER function to monitor key operational readouts.

These methods allow you to diagnose and verify the controller’s operation without an external display.

This answer is automatically generated

Luis Daniel Margall
February 28, 2025

A brumby electrical truck that has a zapi inv.dace2, records the failure 244 "Warning Slave It depends on the supervisor uc", and the alarm 248 "Mc is Opened, eb is applied". On the other hand, the LED does not turn on, but in the manual I did not find the LED code. I would like more certainty about whether the failure is from the controller and the LED code for this Zapi model.

1 comments:
Mr. Anderson
February 28, 2025

Failure 244 "Warning Slave" depends on the supervisor microcontroller (µC). No specific effect or troubleshooting steps are provided in the available context.

Alarm 248 "MC is Opened, EB is Applied" indicates that the main contactor (MC) is open, and the electric brake (EB) is applied. This typically occurs during start-up, standby, or other system states.

The LED code for this model is not explicitly provided in the available context.