Error code
STALL ROTOR
CONTROLLER MISM.
EEPROM KO
PARAM RESTORE
HW FAULT EV.
LOGIC FAILURE #3
LOGIC FAILURE #2
LOGIC FAILURE #1
VKEY OFF SHORTED
CONT. DRV. EV
DRV. SHOR. EV
OPEN COIL EV.
LC COIL OPEN
IQ MISMATCHED
PEB NOT OK
AUX BATT. SHORT.
INIT VMN LOW
VMN LOW
INIT VMN HIGH
VMN HIGH
HW FAULT
HW FAULT EB.
POSITIVE LC OPEN
FIELD ORIENT. KO
CONTACTOR CLOSED
CONTACTOR OPEN
POWER MISMATCH
EB. DRIV.SHRT.
WRONG SET BAT.
WRONG KEY VOLT.
Page 124/169
Effect
Traction/Pump stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Controller works using default
parameters
No effect
MC is not closed, EB is applied,
Traction/Pump stopped
MC is opened, EB is applied,
Traction/Pump, valves stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
MC is not closed, EB is applied,
Traction/Pump stopped
Valves stopped
Valves stopped
MC remains closed, EB is
applied, Traction/Pump, valves
stopped (the command is
released)
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Traction is stopped, MC is opened
Pump motor stopped, valves
stopped
None
MC is not closed, EB is applied,
Traction/Pump, valves stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
MC is not closed, EB is applied,
Traction/Pump stopped
MC is opened, EB is applied,
Traction/Pump stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
MC is opened, EB is applied,
Traction/Pump, valves stopped
MC is not closed (command is not
activated), EB is applied,
Traction/Pump stopped
MC is opened, EB is applied,
Traction/Pump, valves stopped
Traction is stopped, EB is applied,
MC is opened
MC remains closed, EB is applied
(the command is released),
Traction/Pump, valves stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Restart
Condition
procedure
Valves or
Start-up, stand-by,
Traction/Pump
running
request
Install the correct
Start-up
software and Key
re-cycle
Start-up, stand-by,
running
Traction/Pump
Start-up
request
Start-up
Key re-cycle
Valves or
Start-up, stand-by
Traction/Pump
request
Valves or
Start-up, stand-by,
Traction/Pump
request
Valves or
Stand-by, running
Traction/Pump
request
Start-up
Key re-cycle
Start-up, stand-by,
Valves request
running
Valves or
Start-up, stand-by,
Traction/Pump
running
request
Valves or
Start-up, Stand-by,
Traction/Pump
running
Request
Valves or
Start-up, stand-by,
Traction/Pump
running
request
Valves or
Running
Traction/Pump
request
Start-up, stand-by,
Valves request
running
Start-up, stand-by,
running
Valves or
Start-up
Traction/Pump
request
Valves or
Start-up
Traction/Pump
request
Valves or
Start-up
Traction/Pump
request
Valves or
Start-up, stand-by
Traction/Pump
request
Start-up
Key re-cycle
Start-up
Key re-cycle
Valves or
Start-up, stand-by,
Traction/Pump
running
request
Valves or
Running
Traction/Pump
request
Valves or
Start-up
Traction/Pump
request
Valves or
Start-up, stand-by,
Traction/Pump
running
request
Traction/Pump
Running
request
Valves or
Stand-by, running
Traction/Pump
Request
Start-up
Start-up
AFNZPxxx – DUALACE2 NEW GENERATION – User Manual
MDI /
CAN
ZAPI
LED
OPEN
CODE
CODE
CODE
11
FFD3
211
12
FFEF
239
13
3610
208
14
0
209
16
FFEE
238
17
FF11
17
18
FF12
18
19
5114
19
20
5101
220
21
FFE8
232
21
FFF9
234
21
FFF2
242
22
FFE6
230
24
FFF5
245
25
FFDB
217
27
5001
194
30
3121
207
30
3120
30
31
3111
206
31
3110
31
32
FFE3
227
34
FFE5
229
35
FFD5
213
36
FFFD
253
37
5442
37
38
5441
38
39
FFD4
212
40
3222
254
41
3100
251
41
3101
170

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DUALACE2 NEW GENERATION and is the answer not in the manual?

Questions and answers

Giraldo Rubio Lazo
January 28, 2025

Como comprobar el funcionamiento del controlador dualac2 sin display

1 comments:
Mr. Anderson
February 10, 2025

You can check the operation of the Zapi DUALACE2 NEW GENERATION controller without a display using the following methods:

1. Zapi Smart Console – Connect the Zapi Smart Console to the CAN bus to access diagnostics and parameter settings.
2. PC CAN Console – Use the PC CAN Console software to monitor and adjust controller settings.
3. Self-Diagnosis Feature – The controller performs self-diagnosis, and faults can be displayed using Zapi tools.
4. Alarm History Log – Check the log of alarms to review past faults and system behavior.
5. TESTER Function – Use the TESTER function to monitor key operational readouts.

These methods allow you to diagnose and verify the controller’s operation without an external display.

This answer is automatically generated

Luis Daniel Margall
February 28, 2025

A brumby electrical truck that has a zapi inv.dace2, records the failure 244 "Warning Slave It depends on the supervisor uc", and the alarm 248 "Mc is Opened, eb is applied". On the other hand, the LED does not turn on, but in the manual I did not find the LED code. I would like more certainty about whether the failure is from the controller and the LED code for this Zapi model.

1 comments:
Mr. Anderson
February 28, 2025

Failure 244 "Warning Slave" depends on the supervisor microcontroller (µC). No specific effect or troubleshooting steps are provided in the available context.

Alarm 248 "MC is Opened, EB is Applied" indicates that the main contactor (MC) is open, and the electric brake (EB) is applied. This typically occurs during start-up, standby, or other system states.

The LED code for this model is not explicitly provided in the available context.