Error code
EB. DRIV.OPEN
EB. COIL OPEN
HANDBRAKE
MOT.PHASE SH.
THROTTLE PR‚
LIFT+LOWER
TILLER OPEN
STBY I HIGH
OVERLOAD
CAPACITOR CHARGE
THERMIC SENS. KO
TH. PROTECTION
BRAKE RUN OUT
TILLER ERROR
MOTOR TEMPERAT.
MOTOR TEMP. STOP
NO CAN MSG.
SENS MOT TEMP KO
SMARTDRIVER KO
EPS RELAY OPEN
WRONG RAM MEM.
DRIVER SHORTED
CONTACTOR DRIVER
COIL SHOR. MC
VDC LINK OVERV.
VACC NOT OK
INCORRECT START
PUMP INC START
FORW + BACK
SPEED FB. ERROR
AFNZPxxx– DUALACE2 NEW GENERATION – User Manual
Effect
MC remains closed, EB is applied
(the command is released),
Traction/Pump, valves stopped
MC remains closed, EB is applied
(the command is released),
Traction/Pump, valves stopped
Traction/Pump motor is stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
MC remains closed, EB is applied
(the command is released),
Traction stopped
Pump is stopped
LC opens
MC is not closed, EB is applied,
Traction/Pump stopped
MC is not closed, EB is applied,
Traction/Pump stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Maximum current is reduced
according to parameter MOT.T.
T.CUTBACK and speed is
reduced to a fixed value.
Traction controller reduces the
max current linearly from Imax
(85°C) down to 0 A (105°C)
Traction is stopped
Traction stopped, EB applied
Maximum current is linearly
reduced (see paragraph 9.15) and
speed is reduced to a fixed value.
EB is applied, Traction/Pump,
valves stopped
MC is opened, EB is applied,
Traction/Pump, valves stopped
Maximum current is reduced
according to parameter MOT.T.
T.CUTBACK and speed is
reduced to a fixed value.
MC is not closed, Traction/Pump,
valves stopped
Traction/Pump motor is stopped
MC is opened, EB is applied,
Traction/Pump, valves stopped
MC is opened (the command is
released), EB is applied,
Traction/Pump, valves stopped
MC is opened (the command is
released), EB is applied,
Traction/Pump, valves stopped
MC is opened, EB is applied,
Traction/Pump, valves stopped
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Traction/Pump motor is stopped
Traction/Pump motor is stopped
Pump motor is stopped
Traction is stopped
MC is opened , EB is applied,
EVP stopped
Restart
Condition
procedure
Valves or
Running
Traction/Pump
Request
Valves or
Start-up, Stand-by,
Traction/Pump
running
Request
Start-up, stand-by,
Traction/Pump
running
request
Traction/Pump
Start-up
request
Valves or
Start-up, Stand-by,
Traction/Pump
running
Request
Start-up, stand-by,
Pump request
running
Valves or
Start-up, stand-by,
Traction/Pump
running
Request
Valves or
Start-up, stand-by
Traction/Pump
request
Valves or
Running
Traction/Pump
request
Valves or
Start-up
Traction/Pump
request
Start-up, stand-by,
running
Start-up, stand-by,
running
Start-up, stand-by,
Traction/Pump
running
Request
Valves or
Stand-by, running
Traction/Pump
Request
Start-up, stand-by,
running
Start-up, stand-by,
running
Valves or
Start-up, stand-by,
Traction/Pump
running
request
Start-up, stand-by,
running
Start-up
Key re-cycle
Valves or
Start-up, stand-by,
Traction/Pump
Running
request
Stand-by
Key re-cycle
Valves or
Start-up, stand-by,
Traction/Pump
running
request
Valves or
Start-up, stand-by,
Traction/Pump
running
request
Start-up
Valves or
(immediately after
Traction/Pump
MC closing), stand-
request
by, running
Valves or
Stand-by, running
Traction/Pump
request
Start-up, stand-by,
Traction/ request
running
Start-up, stand-by
Traction request
Start-up, stand-by,
Pump request
running
Start-up, stand-by,
Traction request
running
Valves or
Running
Traction/Pump
request
MDI /
CAN
ZAPI
LED
OPEN
CODE
CODE
CODE
42
3224
246
43
FFD8
216
46
FFDD
221
47
FFC4
196
48
FFF3
243
49
FFBB
187
0
51
228
53
2311
53
57
FFB4
180
60
3130
60
61
4211
250
62
4210
62
63
FFCC
204
64
FFB9
185
65
4110
65
65
FFB2
178
67
8130
248
68
4311
218
69
3302
193
70
FFCD
205
71
FFD2
210
74
3211
74
75
3221
75
76
2250
223
77
FFCA
202
78
FF4E
78
79
FF4F
79
79
FFBD
189
80
FF50
80
81
FFAF
175
Page 125/169

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DUALACE2 NEW GENERATION and is the answer not in the manual?

Questions and answers

Giraldo Rubio Lazo
January 28, 2025

Como comprobar el funcionamiento del controlador dualac2 sin display

1 comments:
Mr. Anderson
February 10, 2025

You can check the operation of the Zapi DUALACE2 NEW GENERATION controller without a display using the following methods:

1. Zapi Smart Console – Connect the Zapi Smart Console to the CAN bus to access diagnostics and parameter settings.
2. PC CAN Console – Use the PC CAN Console software to monitor and adjust controller settings.
3. Self-Diagnosis Feature – The controller performs self-diagnosis, and faults can be displayed using Zapi tools.
4. Alarm History Log – Check the log of alarms to review past faults and system behavior.
5. TESTER Function – Use the TESTER function to monitor key operational readouts.

These methods allow you to diagnose and verify the controller’s operation without an external display.

This answer is automatically generated

Luis Daniel Margall
February 28, 2025

A brumby electrical truck that has a zapi inv.dace2, records the failure 244 "Warning Slave It depends on the supervisor uc", and the alarm 248 "Mc is Opened, eb is applied". On the other hand, the LED does not turn on, but in the manual I did not find the LED code. I would like more certainty about whether the failure is from the controller and the LED code for this Zapi model.

1 comments:
Mr. Anderson
February 28, 2025

Failure 244 "Warning Slave" depends on the supervisor microcontroller (µC). No specific effect or troubleshooting steps are provided in the available context.

Alarm 248 "MC is Opened, EB is Applied" indicates that the main contactor (MC) is open, and the electric brake (EB) is applied. This typically occurs during start-up, standby, or other system states.

The LED code for this model is not explicitly provided in the available context.