7.2.2.2 Advanced Configuration

You can set the quantities of the rows and columns of the cabinets loaded by each Ethernet port, the cabinet
connection, as well as the offset of the area loaded by each Ethernet port, so as to complete the whole LED
screen configuration.
Step 1 Click Configuration to enter the screen configuration page.
Step 2 In the Screen Configuration area, select Advanced.
Figure 7-3 Advanced configuration
Step 3 Select an Ethernet port from the drop-down list next to Port.
Step 4 Fill the numbers in the Rows and Columns text boxes to set the quantities of the rows and columns of the
cabinets loaded by the selected Ethernet port.
Step 5 Fill the numbers in the X and Y text boxes to set the starting position of the cabinets loaded by the selected
Ethernet port, that is, the offset of these cabinets. The offset adjustment reference is the top-left corner of
these cabinets.
Step 6 Select an appropriate physical connection mode of the cabinets loaded by the selected Ethernet port in the
Cabinet Connection area.
When a cabinet connection is selected, you can view the real-time effect on LED screen. If all the cabinets of
the screen display normally, that is, no overlapping or repeated images, the cabinet connection is correct.
Note:
Select Mapping to show the relation between each cabinet of the LED screen and the sending device for
easier cabinet connection.
Step 7 Repeat Step 3 to Step 6 to do the same for other Ethernet ports to complete the whole LED screen
configuration.
Step 8 Click Apply to make the settings take effect.