display image, press the knob to save the settings; when you are not satisfied, press
ESC button to exit the current operation and the settings will not be saved.
5.2.2 Advanced Configuration
You can set the cabinet row and column quantities, horizontal offset, vertical offset
and data flow of the cabinets loaded by a single Ethernet port.
Procedure
Step 1 Press the knob to enter the device menu.
Step 2 Rotate the knob to choose Screen Settings > Advanced Configuration, and press
it to enter its submenu.
Step 3 Turn on the advanced configuration function, and then set the cabinet row and
column quantities, horizontal offset, vertical offset and data flow for the target
Ethernet port.
Figure 5-3 Advanced configuration
5.2.3 Save to RV Card
You can send and save the screen configuration to the receiving card. The
configuration data will not be lost after the device is powered off.
5.2.4 More Settings
Step 1 Press the knob to enter the device menu.
Step 2 Rotate the knob to choose Screen Settings > More Settings, and press it to
Mapping
You can turn on this function to display the sequence numbers of Ethernet ports and
cabinets.