Figure 5-6 Import cabinet configuration file
Step 3 Click Add Configuration File and select the desired file from the window that appears.
Step 4 Click Save the Change to HW to save the configuration file to the device.
Send Cabinet Configuration File
After you have added the cabinet configuration file to the device via NovaLCT, you can send the configuration
file to the receiving cards in the cabinets of the LED screen.
Step 1 On the main menu screen, rotate the knob to go to Screen Configuration > Send RCFGx Files.
Step 2 Rotate the knob to select the desired configuration file and press the knob to confirm. The system will
automatically send the selected file to all the receiving cards of the LED screen.
5.2.3 Save to RV Card
After the screen configuration information is sent to the receiving card, you can save the configuration to the
card by using this function so that the configuration data will not be lost after a power failure.
On the main menu screen, go to Screen Configuration > Save to RV Card and press the knob to confirm.
5.2.4 Advanced Configuration
You can set the cabinet row and column quantities, horizontal offset, vertical offset and data flow of the
cabinets loaded by a single Ethernet port.
Step 1 On the main menu screen, go to Screen Configuration > More Settings > Advanced Configuration to
enter the advanced configuration screen.
Step 2 Set the status to On to enable the advanced configuration function.
www.novastar.tech
VX1000 All-in-One Controller User Manual
13