Communication extension card
Bit
13
Pre-excitation
14
DC braking
15
Heartbeat reference
Reference value (REF): The second to twelfth words in a PZD task packet are the main
settings. The main frequency settings are provided by the main setting signal source. Table
2-6 describes the settings of Goodrive350 series VFD.
Function
Word
code
Received
P15.02
PZD2
Received
P15.03
PZD3
Received
P15.04
PZD4
Received
P15.05
PZD5
Received
P15.06
PZD6
Received
P15.07
PZD7
Received
P15.08
PZD8
Received
P15.09
PZD9
Received
P15.10
PZD10
Received
P15.11
PZD11
P15.12
Received
Name
Table 2-6 Settings of Goodrive350 series VFD
0: Invalid
1: Set frequency (0–Fmax, unit: 0.01 Hz)
2: PID reference (0–1000, in which 1000 corresponds to
100.0%)
3: PID feedback (0–1000, in which 1000 corresponds to
100.0%)
4: Torque setting (-3000–+3000, in which 1000
corresponds to 100.0% of the rated current of the
motor)
5: Setting of the upper limit of forward running
frequency (0–Fmax, unit: 0.01 Hz)
6: Setting of the upper limit of reverse running
frequency (0–Fmax, unit: 0.01 Hz)
7: Upper limit of the electromotive torque (0–3000, in
which 1000 corresponds to 100.0% of the rated current
of the motor)
8: Upper limit of the brake torque (0–3000, in which
1000 corresponds to 100.0% of the rated current of the
motor)
9: Virtual input terminal command, 0x000–0x3FF
(corresponding to S8, S7, S6, S5, HDIB, HDIA, S4, S3,
S2, and S1 in sequence)
10: Virtual output terminal command, 0x00–0x0F
(corresponding to RO2, RO1, HDO, and Y1 in
sequence)
11: Voltage setting (for V/F separation)
Value
State to be entered/description
consumption to zero
1
Enabling pre-excitation
0
Disabling pre-excitation
1
Enabling DC braking
0
Disabling DC braking
1
Enabling heartbeat
0
Disabling heartbeat
Value range
-10-
PROFIBUS communication card
Default
value
0
0
0
0
0
0
0
0
0
0
0