2.7.4 Calibrating a measuring probe

Jog
Cal. meas.
calipers >
Cycle Start
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Operation/Programming ShopMill (BAS) – 10.04 Edition
If you want to measure your tools automatically, you must first
determine the position of the probe on the machine table with
reference to the machine zero.
Mechanical tool measuring probes are typically shaped like a cube or
a cylindrical disk. Install the probe in the working area of the machine
(on the machine table) and align it relative to the machining axes.
You must use a mill-type calibration tool to calibrate the measuring
probe. You must enter the length and radius/diameter of the tool in the
tool list beforehand.
Move the calibration tool until it is approximately over the center of
the measuring surface of the probe.
Select the "Measure tool" softkey in "Machine Manual" mode.
Press the "Calibrate measuring calipers" softkey.
Choose whether you want to calibrate the length or the length and
the diameter.
Calibrating length only
Press the "Cycle Start" key.
Calibration is automatically executed at the measuring feedrate.
The distance measurements between the machine zero and
measuring probe are calculated and stored in an internal data area.