Equipment Code Numbering for Measuring Instruments

The numbering for the KKS Equipment Code Level follows some general rules.
In the case of measuring instruments, certain ranges of numbers are assigned
different functions. A listing is provided below:
001 to 199
401 to 499
501 to 599

KKS Cabling Coding

Cabling
The cable coding used within the combustion turbine follows the KKS system for
cabling. A listing of the cables may be found in Volume 2.12.1, section 7 of the
I&C manuals. Figure 4 shows the structure of the KKS cable coding system. The
Function Code for the cable designates the origin of the cable, i.e. BFE, would
originate in the BFE switch-gear cabinets. To find the cable's termination go to
Terminal Arrangement Diagram (YB drawings) for the cabinet designated by the
Function Code.
Copying of this document, and giving it to others and use or communication of the contents, are forbidden without express authority. Offenders are liable to the payment of
damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design.
Measuring instruments for remote transmission of
measured values
Measuring instruments for acceptance test
measurements
Measuring instruments for local display of measured
values

Cable Coding

12
BFE 4
Unit
Figure 4 - Cable Coding
Training Center
006
Cable Serial Number
Cable Assignment Area
Function