2
10.04
Cycle Start
Calibrating a length
Jog
Calibration
Length
probe
Cycle Start
Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Operation/Programming ShopMill (BAS) – 10.04 Edition
2.6 Measuring workpiece zero
5. Enter the diameter of the hole
6. Press the "Cycle Start" key.
Calibration starts. First the exact hole center point is determined.
Then the 4 trigger points on the inside wall of the hole are
approached.
1. Attach a 3D probe type tool to the spindle.
2. Position the tool above the surface.
3. In "Machine Manual" mode, select the "Meas. workp." softkey.
4. Press the "Calibration probe" and "Length" softkeys.
5. Specify reference point Z0 of the surface, e.g. of the workpiece or
the machine table.
6. Press the "Cycle Start" key.
Calibration starts. The length of the measuring tool is calculated and
entered in the tool list.
2
Operation
2-91