94
Commissioning
9.1.1.3.8 "Position" Menu Item
Different parameters for the I/O module can be set using this menu item:
Figure 52: "Position" Menu Item
Table 63: "Position" Menu Item
Option
Valve set point
Current
Coil current
Control
Set point enable
Jog Mode
[-] / [+]
Dither
Power Amp On
Ramp
Name
Description
The setpoint value can be entered in relation to the nominal current (see
"Valve adjustment" menu item).
The actual value measured is displayed here. The units, "mA" or "%"
depend on the selection made in the "Module parameters" menu item.
Select "Setpoint value release" or "JOG Mode"
For activated "JOG Mode" or "TIP Mode" only:
"JOG Mode": Press button: Actual value changes according to the
•
ramp set (see "Ramp Settings" menu item) until the button is
released again.
•
"TIP Mode": Press button: Actual current is increased according to
the ramp set for the parameterized time.
Activate/deactivate Dither Generator
Activate/deactivate output stage
The selection indicated using the "Ramp settings" menu item can be
changed here. This selection is only enabled if "Setpoint value release"
has been selected.
The following information is displayed here:
•
Current ramp
•
Settings made using the "Ramp settings" menu item
Version 1.3.0, valid from FW/HW-Version 01/01
WAGO-I/O-SYSTEM 750
750-632 Proportional Valve Module
Manual