11.1.3.1.2 Acknowledgement; 11.1.3.1.3 Signaling; Table 70: Acknowledgement; Table 71: Structure Of The Handshake Byte - WAGO 750-632 Manual

Proportional valve module for wago-i/o-system 750
Hide thumbs Also See for 750-632:
Table of Contents

Advertisement

106
Appendix

11.1.3.1.2 Acknowledgement

The following acknowledgements are defined:

Table 70: Acknowledgement

Value Explanation
0
INVALID
1
HOLD ACKNOWLEDGE Signal or confirmation that the channel is ready, but data is
2
RESET ACKNOWLEDGE Response to "RESET REQUEST" when Mailbox in reset.
3 ... 7 -

11.1.3.1.3 Signaling

In signal mode, the handshake byte appears as follows:

Table 71: Structure of the Handshake Byte

Bit 7
Bit 6
0

Table 72: Signaling

Value
0x00
0x32
0x33
(other)
Handshake byte
Bit 5
Bit 4
Bit 3
0
Signal
Explanation
INVALID SIGNAL
RESET SIGNAL
ERROR SIGNAL
-
750-632 Proportional Valve Module
Description
Signals that the receiver has not started operations again after
a reset.
not currently being transferred (e.g. because there is not any
data yet).
(not supported, ignore)
Bit 2
Bit 1
Bit 0
Description
State of the process image with no effect by Mailbox 2.0
Shows that the local Mailbox is in the process of
restarting
Shows that the local Mailbox is in the fault condition
Other values are not considered as signals and are
processed separately in the Status or Control nibble.
Version 1.3.0, valid from FW/HW-Version 01/01
WAGO-I/O-SYSTEM 750
Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

750-632/000-100

Table of Contents