WAGO-I/O-SYSTEM 750
750-632 Proportional Valve Module
4.5.5
Outputs
Table 14: Technical Data ‒ Outputs
Property
Number and type
Features
Frequency (Pulse width modulation)
Dither frequency
Nominal load voltage
Permitted cable length
Load type
Output current, max.
Max. error
Different technical data for applications in hazardous areas!
If the device is used in an application in hazardous areas, it must be labeled
accordingly by the user. This labeled device must only be used in hazardous
areas.
The technical data contained in the ATEX/IECEX certificate are binding in this
application!
Table 15: Different electrical information in accordance with ATEX/IECEX-certificate
Property
Output current (max.).
(at an ambient temperature of 60 °C)
Voltage, field supply
Manual
Version 1.3.0, valid from FW/HW-Version 01/01
Device Description
Value/Dimension
2 channels, PWM signal, bipolar (A+,
A− and B+, B−)
Output stage output, short-circuit-proof
and protected against overload by
channel
50 kHz
250 Hz ... 1 Hz
(step-wise parameterizing)
Voltage, field supply
30 m
Valves, coils
1 ... 600 mH, > 8 Ohm
1-channel mode: 2.0 A
2-channel mode: 1.6 A per channel
+/−4.5 mA
Value/Dimension
1-channel operation: 1.4 A
2-channel operation: 0.8 A per channel
24 VDC (−10 % ... +10 %)
29