Connect Devices
7.3.1

Internal Sensor Supply, Single- or Two-Channel, 2-Wire

With single-channel use, using the displayed connection variant a risk reduction
by max. PL d and max. SIL2 can be achieved.
With two-channel use, using the displayed connection variant a risk reduction by
max. PL e and max. SIL3 can be achieved.

Figure 30: Connection Example: Internal Sensor Supply, 2-Wire

7.3.2

Internal Sensor Supply, Single- or Two-Channel, 3-Wire

With single-channel use, using the displayed connection variant a risk reduction
by max. PL d and max. SIL2 can be achieved.
With two-channel use, using the displayed connection variant a risk reduction by
max. PL e and max. SIL3 can be achieved.

Figure 31: Connection Example: Internal Sensor Supply, 3-Wire