R&S NRP18S Series User Manual page 151

High-power three-path diode power sensors
Hide thumbs Also See for NRP18S Series:
Table of Contents

Advertisement

®
R&S
NRP18S-xx
Figure 10-13: Operation lower limit fail status registers
Querying the register:
STATus:OPERation:LLFail:CONDition?
STATus:OPERation:LLFail[:SUMMary][:EVENt]?
Table 10-15: Used operation lower limit fail status bits and their meaning
Bit no.
1
10.3.8.6
Operation Upper Limit Fail Status Register
The CONDition registers contain information whether a measured value currently
exceeds a configured upper limit. The EVENt registers contain information whether a
measured value exceeded an upper limit value since the last query.
User Manual 1178.3686.02 ─ 05
0
0
1
Lower limit fail
0
2
3
0
0
4
0
5
0
6
7
0
0
8
0
9
10
0
11
0
12
0
0
13
14
0
0
15
Short description
Lower limit fail
+
Bit is set if
Measured value is below the lower limit value.
Remote Control Basics
Status Reporting System
151