8.3.2 Parameter group 1 (Basic)

Parameter
Designation
P1-08
Motor Nom Current
P1-13
SEN Config Select
P1-14
Access key
Table 35:
Parameter group 1 (Basic)
Description
Motor rated Current
By setting the "Motor Nom Current" in the drive, the
motor overload protection is configured to match the
motor rating.
When the measured motor current exceeds "Motor
Nom Current", the decimal points on the display will
flash to indicate an overload condition.
If this condition persists, the drive will eventually trip,
displaying I. t -trP, preventing thermal overload of
the motor.
Configuration of sensor inputs with a fix set of combi-
nations
Entry of the password to get access to the extended
parameter set.
The value to be put in is determined by the level to be
accessed.
Level 2 (access to parameter groups 0 to 8):
P1-14 = P2-32 (factory setting: 101)
Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
8 Parameter list
8.3 Parameter groups for RAMO5
Unit
Min
Max
Amps
0.3
6.6
1
4
0
65535
DS
6.6
1
0
169