8 Parameter list
8.3 Parameter groups for RAMO5
8.3.6 Parameter group 6 (Extended motor control)
Parameter
Designation
P6-05
Action@Underload Motor
P6-08
Change Phasesequence
Motor
174
Table 39:
Parameter group 6 (Extended motor control)
Description
Device reaction after occuring of "Underload Motor".
Possibilities device dependent
0: deactivated
1: Trip (stop)
Changes the sequence of the output phases.
This prevents two phases of the motor cable having to be changed
in case the motor runs in the wrong direction.
0: U–V–W (clockwise rotating field)
1: U–W–V (counterclockwise rotating field)
Note:
Only for RASP5... and RAMO5-W...
Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
Unit
Min
Max
–
0
1
–
0
1
DS
0
0