1 Rapid Link 5 system
1.5 Compliance with UL standards

1.5.3 RASP5

26
RASP5 speed controllers have been tested in accordance with UL 61800-5
and are approved as "listed".
Table 5:
RASP5
Property
Input voltage
Output voltage, maximum
Rated operational voltage for
brake control
Output current
Input current
Frequency
Phases
Output frequency
Field bus input voltage
Motor protection
Thermistor monitoring
Protection class
Ambient temperature, maximum
Table 6:
Short circuit current rating for individual and group protection
Voltage
Short-circuit current, maximum
Interrupting Rating
Devices with an integrated repair switch are approved for use as
motor disconnects (lockout/tagout).
Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
Value
480 V AC
480 V AC
180/207 V DC
230/480 V AC
400/480 V AC
2.5 A (RASP5-2...S1)
4.3 A (RASP5-4...S1)
5.6 A (RASP5-5...S1)
8.5 A (RASP5-8...S1)
2.4 A (RASP5-2...)
4.1 A (RASP5-4...)
5.3 A (RASP5-5...)
7.8 A (RASP5-8...)
50/60 Hz
3
0 - 320 Hz
30 V DC
integrated,
at 105 % of full load
integrated
NEMA 12 / NEMA 12K
40 °C without fan
55 °C with fan
With fuse (UL listed)
With built-in
Without built-
repair switch
in local
disconnect
switch
480 V AC
480 V AC
30 A
30 A
10 kA
65 kA
Circuit-breaker (UL listed)
With built-in
Without built-
repair switch
in local
disconnect
switch
480 V AC
480 V AC
32 A
32 A
10 kA
10 kA